Torque specification of stepper motor (AC) is case of the motor driver driving (half step, AC100V).
(DC) is case of the motor driver driving (half step, DC20V).
PK513PB(AC) pulse speed (half step)[pps] PK513(DC) pulse speed (half step)[pps]
PK523MB(AC) pulse speed (half step)[pps] PK523MB(DC) pulse speed (half step)[pps]
PK524MB(AC) pulse speed (half step)[pps] PK524MB(DC) pulse speed (half step)[pps]
PK525MB(AC) pulse speed (half step)[pps] PK525MB(DC) pulse speed (half step)[pps]
PK544MB(AC) pulse speed (half step)[pps] PK544MB(DC) pulse speed (half step)[pps]
C090P-9015P(AC) pulse speed (half step)[pps] C090P-9015P(DC) pulse speed (half step)[pps]
C087QP-9215P(AC) pulse speed (half step)[pps] C087Q-9215P(DC) pulse speed (half step)[pps]
PK545-B(AC) pulse speed[pps] PK545-B(DC) pulse speed[pps]
PK564-B(AC) pulse speed[pps] PK564-B(DC) pulse speed[pps]
PK566-B(AC) pulse speed[pps] PK566-B(DC) pulse speed[pps]
PK569-B(AC) pulse speed[pps] PK569-B(DC) pulse speed[pps]
Non Default Controller Setting Stage
Models that require a change in the controller's default settings Kohzu standard stage have various types of home position (origin) return method. Thus, if combination of standard stage and standard stepper motor controller (KOSMOS Series), that method should be changed from default in case. It is trouble you, but check the operation manual about stage sensor type and controller setting when you use.
The product should be changed system setting and value of controller setting (SYS No.2)
Stage type Stage model Number Setting value(default:4) Home position (origin) return method
X Linear Stage XA16F-L2101 (-R) 1 Home position return method is determined with zone (datum) sensor.
XA16F-L2201 (-R)
XA16F-L2301 (-R)
XA20F-L2401 (-R)
XA20F-L2501 (-R)
SXA0530-R01 (-R)
SXA0750-R01 (-R)
SXA0775-R02 (-R)
SXA1075-R01 (-R)
XY Linear Stage YA16F-L21101 1 Home position return method is determined with zone (datum) sensor.
YA16F-L22101
YA16F-L22201
YA16F-L23101
YA16F-L23101
YA16F-L23301
SYA0530-R01
SYA0750-R01
SYA0775-R02
SYA1075-R01
Vertical Stage ZA04A-W101 7 or 8 Home position return method is determined with limit sensor.
ZA10A-32F01 1 Home position return method is determined with zone (datum) sensor.
ZA16A-32F01
Rotation Stage RA04A-W101 7 or 8 Home position return method is determined with limit sensor.
Wiring of Feedback Positioning Stage
Positioning stage equipped with encoder (Custom made) Positioning stage equipped with linear scale provides higher accuracy than standard stage. Especially, accuracy of lost motion and repeatability should be improved.
And, we supply the feedback cable as an option which used for transmitting the incremental signal of linear scale into the motor controller.
If you need more quickly and higher accuracy positioning, please contact our sales department.
Wiring of Feedback Positioning Stage
System component in case of Kohzu controller
System component in case of Kohzu controller
System component in case of by customer's controller
System component in case of by customer's controller
FAQ